Contrast-enhanced ultrasound evaluation of pancreatic cancer xenografts in nude mice after irradiation with sub-threshold focused ultrasound for tumor ablation

Yi Hui Gao, Lei Wu, Rui Wang, Qian Guo, Yi Ni Chen, Bing Hu and Li Xin Jiang _

PDF  |  HTML  |  How to cite

Oncotarget. 2017; 8:37584-37593. https://doi.org/10.18632/oncotarget.16621

Metrics: PDF 1343 views  |   HTML 1808 views  |   ?  


Abstract

Yi Hui Gao1,2,*,**, Lei Wu1,2,*,**, Rui Wang1,2, Qian Guo1,2, Yi Ni Chen1,2, Bing Hu1,2 and Li Xin Jiang1,2

1Department of Ultrasonography, Shanghai Jiaotong University Affiliated No. 6 Hospital, Shanghai 200233, PR China

2Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, PR China

*Co-first authors

**These authors have contributed equally to this work

Correspondence to:

Li Xin Jiang, email: [email protected]

Keywords: dynamic contrast-enhanced ultrasound, pancreatic cancer, sub-threshold focused ultrasound, evaluation with DCE-US, B-mode US examination

Received: January 20, 2017    Accepted: March 09, 2017    Published: March 28, 2017

ABSTRACT

We evaluated the efficacy of contrast-enhanced ultrasound for assessing tumors after irradiation with sub-threshold focused ultrasound (FUS) ablation in pancreatic cancer xenografts in nude mice. Thirty tumor-bearing nude mice were divided into three groups: Group A received sham irradiation, Group B received a moderate-acoustic energy dose (sub-threshold), and Group C received a high-acoustic energy dose. In Group B, B-mode ultrasound (US), color Doppler US, and dynamic contrast-enhanced ultrasound (DCE-US) studies were conducted before and after irradiation. After irradiation, tumor growth was inhibited in Group B, and the tumors shrank in Group C. In Group A, the tumor sizes were unchanged. In Group B, contrast-enhanced ultrasound (CEUS) images showed a rapid rush of contrast agent into and out of tumors before irradiation. After irradiation, CEUS revealed contrast agent perfusion only at the tumor periphery and irregular, un-perfused volumes of contrast agent within the tumors. DCE-US perfusion parameters, including peak intensity (PI) and area under the curve (AUC), had decreased 24 hours after irradiation. PI and AUC were increased 48 hours and 2weeks after irradiation. Time to peak (TP) and sharpness were increased 24 hours after irradiation. TP decreased at 48 hours and 2 weeks after irradiation. CEUS is thus an effective method for early evaluation after irradiation with sub-threshold FUS.