Oncotarget

Research Papers:

Diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B: a meta-analysis of diagnostic test

Zhi Yin _, Jin Zou, Qiongxuan Li and Lizhang Chen

PDF  |  HTML  |  How to cite

Oncotarget. 2017; 8:22944-22953. https://doi.org/10.18632/oncotarget.14430

Metrics: PDF 1668 views  |   HTML 1957 views  |   ?  


Abstract

Zhi Yin1,2, Jin Zou3, Qiongxuan Li1, Lizhang Chen1

1Department of Epidemiology and Health Statistics, Xiangya School of Public Health, Central South University, Changsha, Hunan Province 410078, China

2Division of Recruitment and Employment, University of South China, Hengyang, Hunan Province 421001, China

3Department of Cardiology, The First Affiliated Hospital of University of South China, Hengyang, Hunan Province 421001, China

Correspondence to:

Lizhang Chen, email: [email protected]

Keywords: liver fibrosis, hepatitis B, FIB-4, meta-analysis

Received: November 14, 2016    Accepted: December 13, 2016    Published: January 02, 2017

ABSTRACT

This study is aimed at evaluating the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B through a meta-analysis of diagnostic test. We conducted a comprehensive search in the Pubmed, Embase, Web of Science, and Chinese National Knowledge Infrastructure before October 31, 2016. Stata 14.0 software was used for calculation and statistical analyses. We used the sensitivity, specificity, positive and negative likelihood ratio (PLR, NLR), diagnostic odds ratio (DOR) and 95% confidence intervals (CIs) to evaluate the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B. Twenty-six studies were included in the final analyses, with a total of 8274 individuals. The pooled parameters are calculated from all studies: sensitivity of 0.69 (95%CI:0.63-0.75), specificity of 0.81 (95%CI: 0.73-0.87), PLR of 3.63 (95%CI:2.66-4.94), NLR of 0.38 (95%CI:0.32-0.44), DOR of 9.57 (95%CI: 6.67-13.74), and area under the curve (AUC) of 0.80 (95%CI: 0.76-0.83). We also conducted subgroup based on the range of cut-off values. Results from subgroup analysis showed that cut-off was the source of heterogeneity in the present study. The sensitivity and specificity of cut-off>2 were 0.69 and 0.95 with the AUC of 0.90 (95%CI: 0.87-0.92). The overall diagnostic value of FIB-4 is not very high for liver fibrosis in patients with hepatitis B. However, the diagnostic value is affected by the cut-off value. FIB-4 has relatively high diagnostic value for detecting liver fibrosis in patients with hepatitis B when the diagnostic threshold value is more than 2.0.


Creative Commons License All site content, except where otherwise noted, is licensed under a Creative Commons Attribution 4.0 License.
PII: 14430